Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Remove X14 pump connector from the PCB
Remove X14 pump connector from the PCB
Measurement:
Test 1.
Measure for resistance across pins 1 (Brown) and 2 (Blue) of X14.
Expected resistance greater than 1MOhm (or O.L).
Test 2.
Measure for resistance across pin 1 (Brown) and a suitable Earth
Expected resistance greater than 1MOhm (or O.L).
Test 3.
Measure for resistance across pin 2 (Blue) and a suitable Earth
Expected resistance greater than 1MOhm (or O.L).
Measure for resistance across pins 1 (Brown) and 2 (Blue) of X14.
Expected resistance greater than 1MOhm (or O.L).
Test 2.
Measure for resistance across pin 1 (Brown) and a suitable Earth
Expected resistance greater than 1MOhm (or O.L).
Test 3.
Measure for resistance across pin 2 (Blue) and a suitable Earth
Expected resistance greater than 1MOhm (or O.L).

Isolate as per TOPs P4
and refit as necessary