Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Remove electrical connector to diverter valve and make safe
Ensure NO demands are present
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1. Measure for DC voltage across connector X2 pin 8 (red lead) and a suitable earth connection.
Reset appliance (press reset button for 2 seconds and release), as the boiler resets the DC voltage at connector X2 pin 8 (red lead) should be seen to fluctuate between 0 - 20 Vdc then return approximately to 0 Vdc.
Test 2. Measure for DC voltage across connector X2 pin 18 (purple lead) and a suitable earth connection.
Reset appliance (press reset button for 2 seconds and release), as the boiler resets the DC voltage at connector X2 pin 18 (purple lead) should be seen to fluctuate between 0 - 20 Vdc then return approximately to 0 Vdc.