Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the connector from the DHW flow sensor and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC volts across pin 3 (yellow lead) connector X2 and a suitable earth connection.
Expected voltage approximately 4.8 Vdc.
Note.
Ensure a good connection is made or misdiagnosis may occur.
Expected voltage approximately 4.8 Vdc.
Note.
Ensure a good connection is made or misdiagnosis may occur.

Isolate as per TOPs P4
and refit as necessary