Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
DHW temperature set to MAX
Attach temperature clamp to flow pipe of the primary heat exchanger
Attach temperature clamp to flow pipe of the primary heat exchanger
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow self-check to complete and appliance
to operate for hot water for 3 minutes.
Monitor the temperature differential across flow and return pipes.
Expected temperature differential approximately 30°C or less.
Note:
Ensure a good connection is made with the flow & return pipes
or misdiagnosis will occur
to operate for hot water for 3 minutes.
Monitor the temperature differential across flow and return pipes.
Expected temperature differential approximately 30°C or less.
Note:
Ensure a good connection is made with the flow & return pipes
or misdiagnosis will occur