Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Remove one lead from the gas valve modureg coil
Attach pressure gauge to gas valve pressure outlet test point
Attach pressure gauge to gas valve pressure outlet test point
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance if required (rotate selector switch to
'O' position, then rotate back to DHW/CH position).
Allow self-check to complete and appliance to commence its ignition sequence.
Measure the minimum burner pressure.
Minimum burner pressure should be as per table opposite.
'O' position, then rotate back to DHW/CH position).
Allow self-check to complete and appliance to commence its ignition sequence.
Measure the minimum burner pressure.
Minimum burner pressure should be as per table opposite.
Isolate as per TOPs P4
and refit as necessary