Set Appliance State:
Turn Hot Water Tap On
DHW temperature set to MAX
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Allow self-check to complete and the appliance to ignite and run for the DHW demand.
With a flow rate of :
Betacom 24C: 9.4 litres / min
Betacom 30C: 10.5 litres / min
Is there a temperature rise of approximately 35°C is operation satisfactory?
Note.
1. A flow rate less stated above will result in a higher temperature rise. To investigate poor flow rate click HERE.
2. If fault code overheat occurs during DHW operation CLICK HERE
With a flow rate of :
Betacom 24C: 9.4 litres / min
Betacom 30C: 10.5 litres / min
Is there a temperature rise of approximately 35°C is operation satisfactory?
Note.
1. A flow rate less stated above will result in a higher temperature rise. To investigate poor flow rate click HERE.
2. If fault code overheat occurs during DHW operation CLICK HERE