Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
Remove electrical connector from the diverter valve actuator
and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow self-check to complete.
Measure for AC voltage across pin 13 (white lead) of X19
connector and a suitable earth point.
Expect mains voltage.
Note.
1. Ensure a good connection is made with test probes.
2. Harness colours may change, but test points remain the same.