Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Place PCB in test position, click HERE for guidance
Place PCB in test position, click HERE for guidance
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure voltage between brown (8) and earth at X401.
Expect approx. 33 VDC.
Expect approx. 33 VDC.

Isolate as per TOPs P4