Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the 3 wire connector from the fan
Measurement:
Test 1:
Measure the resistance between terminal 1 and 3.
Expected resistance 1 MOhm or greater.
Test 2:
Measure the resistance between terminal 3 and 2.
Expected resistance 1 MOhm or greater.
Measure the resistance between terminal 1 and 3.
Expected resistance 1 MOhm or greater.
Test 2:
Measure the resistance between terminal 3 and 2.
Expected resistance 1 MOhm or greater.

Isolate as per TOPs P4
and refit as necessary