Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove mains voltage connector to fan assembly
Measurement:
Test 1:
Measure the resistance between the terminals 2 and 3 at the fan assembly.
Expected resistance greater than 1 Mohm.
Test 2:
Measure the resistance between the terminals 1 and 2 at the fan assembly.
Expected resistance greater than 1 Mohm.
Test 3:
Measure the resistance between the terminals 1 and 3 at the fan assembly.
Expected resistance greater than 1 Mohm.
Measure the resistance between the terminals 2 and 3 at the fan assembly.
Expected resistance greater than 1 Mohm.
Test 2:
Measure the resistance between the terminals 1 and 2 at the fan assembly.
Expected resistance greater than 1 Mohm.
Test 3:
Measure the resistance between the terminals 1 and 3 at the fan assembly.
Expected resistance greater than 1 Mohm.

Isolate as per TOPs P4
and refit as necessary