Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector 100 from the PCB
Measurement:
Test 1:
Measure the resistance between the brown and blue wires at the disconnected connector.
Expected resistance greater than 1 Mohm.
Test 2:
Measure the resistance between the blue and a suitable earth connection.
Expected resistance greater than 1 Mohm
Test 3:
Measure the resistance between brown and a suitable earth connection.
Expected resistance greater than 1 Mohm
Measure the resistance between the brown and blue wires at the disconnected connector.
Expected resistance greater than 1 Mohm.
Test 2:
Measure the resistance between the blue and a suitable earth connection.
Expected resistance greater than 1 Mohm
Test 3:
Measure the resistance between brown and a suitable earth connection.
Expected resistance greater than 1 Mohm

Isolate as per TOPs P4
and refit as necessary