Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector 35 from the PCB
Measurement:
Test 1.
Measure for resistance across the blue and brown wires of connector 35.
Expected resistance approximately 4.1 Kohms.
Test 2:
Measure the resistance between the blue and a suitable earth connection.
Expected resistance greater than 1 Mohm
Measure for resistance across the blue and brown wires of connector 35.
Expected resistance approximately 4.1 Kohms.
Test 2:
Measure the resistance between the blue and a suitable earth connection.
Expected resistance greater than 1 Mohm

Isolate as per TOPs P4
and refit as necessary