Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove low voltage connector from fan (5 pin plug)
Pull X5 back slightly to expose test pins

Measurement:

Check for continuity (zero resistance) of each of the
3 wires running between X5 and the disconnected plug.
Black = X5 Pin 4
Yellow = X5 Pin 5
Pink = X5 Pin 6.
Inspect harness and connectors for good overall condition.
Note:
Wires may be multicoloured.