Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove low voltage connector from fan (5 pin plug)
Pull X5 back slightly to expose test pins
Pull X5 back slightly to expose test pins
Measurement:
Check for continuity (zero resistance) of each of the
3 wires running between X5 and the disconnected plug.
Black = X5 Pin 4
Yellow = X5 Pin 5
Pink = X5 Pin 6.
Inspect harness and connectors for good overall condition.
Note:
Wires may be multicoloured.
3 wires running between X5 and the disconnected plug.
Black = X5 Pin 4
Yellow = X5 Pin 5
Pink = X5 Pin 6.
Inspect harness and connectors for good overall condition.
Note:
Wires may be multicoloured.

Isolate as per TOPs P4
and refit as necessary