Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB
Disconnect plug X8 from the PCB
Disconnect plug X8 from the PCB
Measurement:
Measure the resistance between pin 5 (grey) and pin 4 (black) at connector X8.
| Isolate Mains Power to appliance as per TOPs P4 |
| Temperature Range (°C) | Resistance Range |
|---|---|
| -30°C to -20°C | 100.0kΩ - 190.0kΩ |
| -20°C to -10°C | 57.0kΩ - 100.0kΩ |
| -10°C to 0°C | 33.0kΩ - 57.0kΩ |
| 0°C to 5°C | 25.0kΩ - 33.0kΩ |
| 5°C to 10°C | 20.0kΩ - 25.0kΩ |
| 10°C to 15°C | 16.0kΩ - 20.0kΩ |
| 15°C to 20°C | 12.5kΩ - 16.0kΩ |
| 20°C to 30°C | 8.1kΩ - 12.5kΩ |
| 30°C to 40°C | 5.3kΩ - 8.1kΩ |
| 40°C to 50°C | 3.6kΩ - 5.3kΩ |