Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the 2 red wires from the fan connector
Measurement:
Test 1:
Measure the resistance between the 2 exposed fan connector terminal.
Expect a resistance of between 40 and 95 Ohms.
Test 2:
Measure the resistance between one of the fan terminals and a suitable earth.
Expect a resistance of 1MOhm or greater.
(O.L is acceptable because this is greater than 1MOhm)
Are the resistances measured as expected?
Measure the resistance between the 2 exposed fan connector terminal.
Expect a resistance of between 40 and 95 Ohms.
Test 2:
Measure the resistance between one of the fan terminals and a suitable earth.
Expect a resistance of 1MOhm or greater.
(O.L is acceptable because this is greater than 1MOhm)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary