Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Remove combined fan, gas valve and combustion chamber assembly from the top of the primary heat exchanger
Remove the burner
Remove the burner
Observation:
Thoroughly inspect the burner assembly for damage, restrictions and/or blockages.
Note.
1. If burner inspection is satisfactory do not reassemble proceed to next inspection.
2. New gaskets shall be used when the burner/combustion chamber assembly is refitted.
Note.
1. If burner inspection is satisfactory do not reassemble proceed to next inspection.
2. New gaskets shall be used when the burner/combustion chamber assembly is refitted.
Isolate as per TOPs P4
and refit as necessary