Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
Remove electrical connector to spark generator and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance if required.
(press and hold the reset button for 4 seconds then release)
Measure for DC voltage across brown lead on connector X21 and an earth (use the copper pipe to the gas valve as earth).
Approximately 85 Vdc should be present, as the appliance goes through its ignition cycle the voltage should increase to approximately 365 Vdc as the PCB sends power to the spark generator then return to 85 Vdc before the next ignition attempt.
Does the voltage behave as described above?