Set Appliance State:

Mains Power Off
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Observation:

Set boiler control switch to O position.
Allow the boiler to self check.
Does the boiler remain in standby state and not start its ignition sequence?
Note:
The boiler has automatic frost protection, if the water temperature within the boiler is below 5 degrees C then the boiler will fire until a return temperature of 10 degrees C is reached.
During this time an 'H' will be shown on the display.