Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Gain access to PCB (use Insulation Mat as required)
Disconnect wires from APS making a note of their connections

Measurement:

Note the operating pressure indicated on the pressure switch.
Connect the air pressure switch charge kit to +ve connection on the air pressure switch, disconnect the -ve connection.
Increase the pressure via the syringe to that indicated on the pressure switch. Continuity (zero resistance) should then be measured across the Common and NO terminals at the APS.
Notes:
If continuity is not measured it is permissible
to increase the pressure by up to 50%
If continuity is measured make a note of the pressure and keep air pressure switch charge kit connected to air pressure switch.