Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect 7 way connector (yellow and brown wires) from the PCB

Measurement:

Test 1:
Measure resistance between the pump feed and the neutral wire at the connector block.
Expected resistance greater than 80 Ohms for standard pumps and greater than 1MOhm for ErP pumps.
Test 2:
Measure resistance between the pump feed and the earth wire at the connector block.
Expected resistance above 1 MOhm.
Note:
This test is for systems where
the pump is wired into the boiler.
If the pump is not wired into the boiler
then choose "Resistance as expected".