Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between pin 9 (orange) at X3 on the main PCB to a suitable earth point.
Mains voltage should be present.
Mains voltage should be present.

Isolate as per TOPs P4
and refit as necessary