Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect the brown wires from the selector switch
Selector switch in CH & HW mode

Measurement:

Measure the resistance between the exposed spade connectors.
Resistance should be short circuit (zero resistance).