Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove spark and earth leads from electrode and spark generator
Measurement:
Test 1:
Measure the resistance across the ignition lead. There are two types of ignition lead.
If a red ignition cap lead is fitted expect short circuit / zero resistance across the lead.
If black ignition cap lead is fitted expect approximately 1 KOhm across the lead.
Test 2:
Measure the resistance across the earth lead.
Resistance should be short circuit / zero resistance.
Inspect the leads for good overall condition and that
they fit securely to the electrode and spark generator.
Measure the resistance across the ignition lead. There are two types of ignition lead.
If a red ignition cap lead is fitted expect short circuit / zero resistance across the lead.
If black ignition cap lead is fitted expect approximately 1 KOhm across the lead.
Test 2:
Measure the resistance across the earth lead.
Resistance should be short circuit / zero resistance.
Inspect the leads for good overall condition and that
they fit securely to the electrode and spark generator.

Isolate as per TOPs P4
and refit as necessary