Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
CH Demand
Hinge down the PCB housing
Attach pressure gauge to the inlet pressure test point
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset lockout as necessary.
Allow fan to run and ignition sequence to commence.
Does the inlet pressure remain constant and above a minimum of 18.1mb throughout the operation or does it die away?
Note:
When pressure gauge is removed pressure test point should be tightened & checked for gas soundness.