Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Hinge down the PCB housing
Position PCB as illustrated in image
Disconnect fan connector at the fan and make safe
Disconnect fan connector at the fan and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Test 1:
Measure for DC volts across the white wire of illustrated connector to a suitable neutral.
Expected voltage approx. 13.4V DC.
Test 2:
Measure for DC volts across the green wire of illustrated connector to a suitable neutral.
Expected voltage approx. 0V DC.
Measure for DC volts across the white wire of illustrated connector to a suitable neutral.
Expected voltage approx. 13.4V DC.
Test 2:
Measure for DC volts across the green wire of illustrated connector to a suitable neutral.
Expected voltage approx. 0V DC.

Isolate as per TOPs P4
and refit as necessary