Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
CH Demand
Hinge down the PCB housing
Reset lockout as necessary
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow ignition sequence to commence and sparking heard.
Measure the voltage on the red wire and the adjacent black wire at the 6 way connector at the top of the PCB housing.
Expect approximately 215V DC.
WARNING!
Sparking will occur during the test. Ensure hands are kept well clear of the
spark lead.