Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect wires from pump
(pump is fitted external to appliance)
(pump is fitted external to appliance)
Measurement:
Test 1:
Measure the resistance across pump L and N
Expected resistance greater than 80 Ohms for standard pumps and greater than 1MOhm for ErP pumps.
Test 2:
Measure the resistance across pump L and pump earth.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance across pump N and pump earth.
Resistance should be greater than 1M Ohm.
Measure the resistance across pump L and N
Expected resistance greater than 80 Ohms for standard pumps and greater than 1MOhm for ErP pumps.
Test 2:
Measure the resistance across pump L and pump earth.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance across pump N and pump earth.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary