Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Hinge down the PCB housing
Remove 8 way connector from pcb

Measurement:

Measure resistance between the purple wires and then between the blue wires fitted to the low voltage harness.
Resistance depends on kW selector setting but should conform approximately to the table below.
kW Selector SettingPurple WiresBlue Wires
1 (12kW output)150kOhms6.2kOhms
2 (15kW output)13kOhms68kOhms
3 (18kW output)150KOhms68kOhms
4 (24kW output)36kOhms1.5kOhms
5 (30kW output)36kOhms16kOhms