Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the 3 wire connector from the fan assembly
Remove connector X2 from the PCB
Remove connector X2 from the PCB
Measurement:
Test 1:
Measure the resistance of the brown wire at the fan connector to pin 3 on connector X2.
Expect continuity / zero resistance.
Test 2:
Measure the resistance of the blue wire at the fan connector to pin 4 on connector X2.
Expect continuity / zero resistance.
Also visually inspect the condition of the harness.
Are the resistances as expected and is the harness in good condition?
Measure the resistance of the brown wire at the fan connector to pin 3 on connector X2.
Expect continuity / zero resistance.
Test 2:
Measure the resistance of the blue wire at the fan connector to pin 4 on connector X2.
Expect continuity / zero resistance.
Also visually inspect the condition of the harness.
Are the resistances as expected and is the harness in good condition?

Isolate as per TOPs P4
and refit as necessary