Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
CH Demand
Hinge down the PCB housing
Attach pressure gauge to the inlet pressure test point
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Ensure no other gas appliances are in use. Allow the ignition sequence to commence.
Observe the Pressure gauge throughout the ignition phase, during the sparking stage of the ignition sequence there should be a notable dip from standing to working pressure as the gas valve opens.
Notes:
1. The inlet pressure should remain above 18mb through the ignition sequence.
2. The appliance will have 5 ignition attempts approximately 5 seconds apart and gas will only pass for approximately 3 seconds on each ignition attempt.
3. When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.