Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X2 from the PCB
Measurement:
Test 1:
Measure the resistance between the two outer wires (pins 2 and 5) of the disconnected X2 plug.
Resistance should be greater than 1M Ohm.
Test 2:
Measure the resistance between pin 5 (brown) to a suitable earth point.
Resistance should be greater than 1M Ohm.
Measure the resistance between the two outer wires (pins 2 and 5) of the disconnected X2 plug.
Resistance should be greater than 1M Ohm.
Test 2:
Measure the resistance between pin 5 (brown) to a suitable earth point.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary