Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the twelve pin connector from PCB
Measurement:
Measure resistance across connections 7 and 8 either side of the black resistor at the disconnected connector.
Expected resistance approx. 8 - 10 kOhms.
Expected resistance approx. 8 - 10 kOhms.

Isolate as per TOPs P4
and refit as necessary