Set Appliance State:
Apply CH demand
Gas On
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Allow boiler to fire.
Remove demand.
Does the burner shut down within 3 seconds?
Remove demand.
Does the burner shut down within 3 seconds?
Isolate as per TOPs P4