Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the 4 pin connector with yellow leads from the PCB
Measurement:
Measure resistance across connections 1 and 4 (yellow) leads at the disconnected connector.
The resistance will vary according the boiler temperature but should conform to the table below:
The resistance will vary according the boiler temperature but should conform to the table below:
| Temperature °C | Resistance in kOhms | 20-30 | 1000-1400 |
| 30-40 | 400-675 |
| 40-50 | 235-400 |
| 50-60 | 144-235 |
| 60-70 | 70-80 |

Isolate as per TOPs P4
and refit as necessary