Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Disconnect connector PL1 from the PCB
Disconnect connector PL1 from the PCB
Measurement:
Measure the resistance across the two yellow wires at PL1.
Resistance will vary according to the temperature of the water.
The lower the temperature the higher the resistance.
The resistance should conform approximately to the table below:
Resistance will vary according to the temperature of the water.
The lower the temperature the higher the resistance.
The resistance should conform approximately to the table below:
| Temperature °C | Resistance in kOhms |
| 20-30 | 1050-780 |
| 30-40 | 780-600 |
| 40-50 | 600-450 |
| 50-60 | 450-260 |
| 60-70 | 260-150 |
| 70-80 | 150-55 |

Isolate as per TOPs P4
and refit as necessary