Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Disconnect wires from the temperature sensor
Disconnect wires from the temperature sensor
Observation:
Measure the resistance across the exposed terminals of the thermistor.
Resistance will vary according to the temperature of the water.
The lower the temperature the higher the resistance.
The resistance should conform approximately to the table below:
Resistance will vary according to the temperature of the water.
The lower the temperature the higher the resistance.
The resistance should conform approximately to the table below:
| Temperature °C | Resistance in kOhms |
| 20-30 | 1050-780 |
| 30-40 | 780-600 |
| 40-50 | 600-450 |
| 50-60 | 450-260 |
| 60-70 | 260-150 |
| 70-80 | 150-55 |

Isolate as per TOPs P4
and refit as necessary