Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
For access behind the control panel
Release the fixing screw located at the top of the case front panel and lift the panel upwards from its locating pins and then forwards from the boiler. Remove the two fixing screws that secure the control panel and lower the panel.
Observation:
Disconnect connector X7 from the PCB.
Check resistances across the connections at the
disconnected connector as per table below:
Check resistances across the connections at the
disconnected connector as per table below:
| Test | Leads | Expected Resistance(Ohms) |
| 1. | Orange and black leads | Infinity (O L on standard meter) |
| 2. | Black lead and Earth | Infinity (O L) |
| 3. | Orange lead and Earth | Infinity (O L) |

Isolate as per TOPs P4
and refit as necessary