Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Disconnect the fan lead connector from the fan
The molex connection has a tag lock that has to be depressed to remove the connector from the fan. This may prove difficult with the fan in situ so it may be easier to disconnect the fan from the venturi housing to gain access to the connector
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Check for voltages at the disconnected plug across the leads listed below:
Test

Leads

Expected Voltage DC

1.

Orange & Brown

3 to 9

2.

Blue & White

3 to 9

3.

Brown & Blue

36

4.

Brown & Black

36