Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the burner assembly from the boiler
Measurement:
Inspect ignition electrode, sensing electrode and burner for general condition.
Thoroughly check the ceramic for damage and ensure the electrode is not distorted.
Check the electrode gaps are as shown.
Note:
Before reassembly check the integrity of all disturbed gaskets and seals and replace as necessary also upon reassembly all disturbed joints should be checked for gas tightness.
Thoroughly check the ceramic for damage and ensure the electrode is not distorted.
Check the electrode gaps are as shown.
Note:
Before reassembly check the integrity of all disturbed gaskets and seals and replace as necessary also upon reassembly all disturbed joints should be checked for gas tightness.
Isolate as per TOPs P4
and refit as necessary