Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove fan
Measurement:
Check fan impeller moves freely.
Check resistances as tabled below:
Note:
The negative probe must be placed on terminal 1
for all tests.
Check resistances as tabled below:
Note:
The negative probe must be placed on terminal 1
for all tests.
| Test | Terminals | Expected Resistance |
| 1. | 1 and 5 | 3.2 MOhms |
| 2. | 1 and 4 | 3.2 MOhms |
| 3. | 1 and 3 | 3.2 MOhms |
| 4. | 1 and 2 | 19.6 MOhms |

Isolate as per TOPs P4
and refit as necessary