Set Appliance State:
Mains Power Off
CH Demand
Mode Switch in HIGH position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Run the boiler in its high operating mode.
Does the Burner shut off when the system reaches the high mode temperature setting
(max flow temp 82 deg C, boiler should not go to overheat/lockout)?
Note:
It may be necessary to reduce the heating load by turning off some radiators to reduce the time taken for this test.
Does the Burner shut off when the system reaches the high mode temperature setting
(max flow temp 82 deg C, boiler should not go to overheat/lockout)?
Note:
It may be necessary to reduce the heating load by turning off some radiators to reduce the time taken for this test.