Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure for a constant voltage across the red and black wires of the 4 way plug on the PCB.
Expect approx 200V - 230V DC.
Note:
Voltage will only be present during the sparking phase of the ignition sequence.
Expect approx 200V - 230V DC.
Note:
Voltage will only be present during the sparking phase of the ignition sequence.

Isolate as per TOPs P4
and refit as necessary