Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH temperature control to max
Disconnect user interaction connector at the PCB
Gain access to User Interaction PCB ensuring that the
CH temperature control remains set to Max
Gain access to User Interaction PCB ensuring that the
CH temperature control remains set to Max
Measurement:
Test 1. Measure for resistance across the CH temperature potentiometer at test point 1 as illustrated - Expected resistance 0 - 10 ohms.
Test 2. Measure for resistance across the CH temperature potentiometer at test point 2 as illustrated - Expected resistance approximately 2.4 KOhms.
Test 2. Measure for resistance across the CH temperature potentiometer at test point 2 as illustrated - Expected resistance approximately 2.4 KOhms.

Isolate as per TOPs P4
and refit as necessary