Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
CH temperature control set to OFF position
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure for A/C voltage across resistor R115 (as illustrated) and a suitable earth connection.
Expected voltage approximately 98 volts A/C.