Set Appliance State:
Mains Power Off
CH Demand
CH temperature control to max
Ensure appliance is cool
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance if required.
Does the burner ignite and establish smoothly?
Note:
1. The boiler will go to ignition lockout (3 red flashes) after 5 attempts to ignite,
reset boiler as required.
2. When the burner is established the chimney sweep led will illuminate green and blink off momentarily every 7 - 9 seconds.
Does the burner ignite and establish smoothly?
Note:
1. The boiler will go to ignition lockout (3 red flashes) after 5 attempts to ignite,
reset boiler as required.
2. When the burner is established the chimney sweep led will illuminate green and blink off momentarily every 7 - 9 seconds.