Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
CH Demand
CH temperature control to max
Gain access to PCB (use Insulation Mat as required)
Remove spark ignition lead from the spark generator and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Reset appliance if required.
Approximately 8 seconds after the fan has started a strong consistent spark should be seen between the spark generator output terminal and the PCB earth connection, this will occur five times before ignition lockout occurs.
Is there a strong consistent spark?
Note:
Reset appliance as required until test complete.