Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect leads from main solenoid (right hand side)

Measurement:

Test 1:
Measure the resistance across the spades of the main solenoid.
Resistance should be approximately 2.1kΩ.
Test 2:
Measure the resistance between either of the spades
of the main solenoid to a suitable earth point.
Resistance should be greater than 1MΩ (or O.L).