Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect gas valve plug from PCB (refer to pictures)

Measurement:

Test 1:
Measure the resistance across the white wire and the
blue wire next to it at the disconnected plug.
Resistance should be approximately 2.1kΩ.
Test 2:
Measure the resistance at white wire at the
disconnected plug to a suitable earth point.
Resistance should be greater than 1MΩ (or O.L).