Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the white wire marked "GV2" to either of the blue wires marked "N" at the gas valve plug on the PCB.
Mains voltage should be present.
Mains voltage should be present.

Isolate as per TOPs P4
and refit as necessary