G.C. NUMBER41 415 91

Next: &11, *

CENTRAL HEATING

BOILER SWITCH IN ON POSITION

Next: &nff, ?23, ?25, ?27

MAIN BURNER IGNITES

BOILER SWITCH IN THE ON POSITION

Next: &1, ?72, ?74

MAIN BURNER ON NEON

BOILER SWITCH IN THE ON POSITION

Next: &2, f20

AIR PRESSURE OK NEON

BOILER SWITCH IN ON POSITION

Next: &3, f19

BOILER ON NEON

BOILER SWITCH IN ON POSITION

Next: &4, f18

OVERHEAT CONDITION: COLD

BOILER SWITCH IN ON POSITION

Next: &5, f17

BOILER OVERHEAT NEON

{ISOLATEMAINSPOWER}<

Next: &6, !f16

ON/OFF SWITCH NEON

BOILER SWITCH IN THE ON POSITION.

Next: &7, !f15

EXTERNAL PUMP RUN CHECK

BOILER SWITCH IN THE ON POSITION
ALL BOILER AND EXTERNAL CONTROLS ARE CALLING FOR HEAT

Next: &8, f14

SYSTEM CHECKS

{ISOLATEMAINSPOWER}
PLEASE ENSURE THAT THE FOLLOWING SYSTEM CHECKS ARE COMPLETED

Next: &9, !f13

IDEAL STELRAD TURBO 2-12KW

G.C. NUMBER 41 415 9

Next: &10, !f12

AIR PRESSURE OK NEON

CONDENSATE

Next: End

AIR PRESSURE OK NEON

FLUE

Next: End

ELECTRICAL CHECK

ELECTRICAL CHECK

Next: End

SYSTEM CHECKS

SYSTEM CHECKS

Next: End

ON/OFF SWITCH NEON

BOILER SWITCH

Next: End

BOILEROVERHEAT NEON

OVERHEAT NEON

Next: End

EXTERNAL PUMP RUN CHECK

MAINS VOLTAGE SUPPLY

Next: End

EXTERNAL PUMP RUN CHECK

PUMP SUPPLY

Next: End

OVERHEAT CONDITION: COLD

FLUE THERMOSTAT

Next: End

BOILER ON NEON

FUSE

Next: End

BOILER ON NEON

AIR PRESSURE SWITCH

Next: End

AIR PRESSURE OK NEON

BURNER FAN CONNECTOR

Next: End

AIR PRESSURE OK NEON

AIR PRESSURE SWITCH TUBES

Next: End

MAIN BURNER ON NEON

ELECTRODE LEAD

Next: End

MAIN BURNER ON NEON

GV1 PILOT SOLENOID

Next: End

MAIN BURNER ON NEON

GAS VALVE

Next: End

CENTRAL HEATING

SUMP

Next: End

OVERHEATED

PUMP

Next: End

BOILER ON NEON

PRINTED CIRCUIT BOARD NO.7 (PCB7)

Next: End

FLAME SENSE

PRINTED CIRCUIT BOARD NO.7 (PCB7)

Next: End

FLAME SENSE2

PRINTED CIRCUIT BOARD NO.7 (PCB7)

Next: End

MAIN BURNER ON NEON

PRINTED CIRCUIT BOARD NO.7 (PCB7)

Next: End

HEAT EXCHANGER NOISY

PUMP

Next: End

AIR PRESSURE OK NEON

AIR PRESSURE SWITCH

Next: End

CENTRAL HEATING

Next: End

EXTERNAL PUMP RUN CHECK

PUMP

Next: End

OVERHEAT CONDITION:COLD

OVERHEAT THERMOSTAT

Next: End

BOILER ON NEON

BOILER CONTROL THERMOSTAT

Next: End

BOILER ON NEON

BOILER ON NEON

Next: End

AIR PRESSURE OK NEON

BURNER FAN

Next: End

AIR PRESSURE OK NEON

AIR PRESSURE SWITCH NEON

Next: End

MAIN BURNER ON NEON

ELECTRODE

Next: End

MAIN BURNER ON NEON

PILOT INJECTOR

Next: End

MAIN BURNER ON NEON

BOILER ON NEON

Next: End

MAIN BURNER IGNITES

GV2 MAIN SOLENOID

Next: End

MAIN BURNER IGNITES

BURNER PLAQUES

Next: End

CENTRAL HEATING

HEAT EXCHANGER

Next: End

CENTRAL HEATING

FLUE THERMOSTAT

Next: End

CENTRAL HEATING

OVERHEAT THERMOSTAT

Next: End

BOILER ON NEON2

PRINTED CIRCUIT BOARD NO.7 (PCB7)

Next: End

HEAT EXCHANGER NOISY

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: p24

HEAT EXCHANGER QUIET

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p26

OVERHEATED

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: p28

DOES NOT LIGHT

CHARACTERISTIC TEST FROM MAIN BURNER IGNITES

Next: !p73

LIGHTS NOISILY

CHARACTERISTIC TEST FROM MAIN BURNER IGNITES

Next: !p75

MAINS 240V INPUT CHECK

BOILER SWITCH IN OFF POSITION

Next: p30, !f29

FLUE THERMOSTAT COLD

Next: !p34, !f33

BOILER THERMOSTAT OUTPUT

BOILER SWITCH IN ON POSITION

Next: p36, f35

FAN RUNNING

BOILER SWITCH IN ON POSITION

Next: p46, f45

PILOT IGNITES

BOILER SWITCH IN ON POSITION

Next: p56, f55

PCB7 CONNECTION 3 VOLTAGE: AIR PRESSURE SWITCH N/C

BOILER SWITCH IN THE ON POSITION

Next: p38, f37

FUSE

{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION

Next: !p93, !f39

FAN VOLTAGE INPUT CHECK

BOILER SWITCH IN ON POSITION

Next: !p48, !f47

AIR PRESSURE SWITCH CONNECTION TUBES

{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION

Next: p99, !f51

PILOT SPARKING

BOILER SWITCH IN ON POSITION

Next: p58, f57

SPARK GENERATOR

BOILER SWITCH IN ON POSITION

Next: p60, !f97

SUMP

{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION

Next: !p81, !f80

FLUE

Next: !p102, !f103

PUMP HOT RUNNING

BURNER SWITCH IN ON POSITION
ALL BOILER AND EXTERNAL CONTROLS ARE CALLING FOR HEAT

Next: !p77, !f98

FLUE THERMOSTAT HOT

Next: p79, f78

WATER PUMP VOLTAGE

BOILER SWITCH IN ON POSITION

Next: !p32, !f31

PCB7 CONNECTION 2 VOLTAGE: FAN VOLTAGE

BOILER SWITCH IN ON POSITION

Next: !p44, !f92

AIR PRESSURE SWITCH: NO AIR

{ISOLATEMAINSPOWER}<

Next: !p42, !f41

AIR PRESSURE SWITCH: AIR DETECT

BOILER SWITCH IN THE ON POSITION

Next: !p50, f49

FLAME SENSE

BOILER SWITCH IN ON POSITION

Next: p68, !f95

PILOT SOLENOID GV1

{ISOLATEMAINSPOWER}
BOILER SWITCH IN OFF POSITION
REMOVE RED AND BLUE LEADS FROM SOLENOID

Next: p64, !f63

SPARK ELECTRODE LEAD

{ISOLATEMAINSPOWER}
REMOVE ELECTRODE LEAD FROM ELECTRODE AND PCB

Next: !p62, !f61

PILOT GAS SUPPLY

{ISOLATEMAINSPOWER}<

Next: !p66, !f65

PCB7 CONNECTION 6: MAIN GAS VALVE VOLTAGE

BOILER SWITCH IN ON POSITION

Next: !p71, !f94

PUMP HOT RUNNING

BURNER SWITCH IN ON POSITION
ALL BOILER AND EXTERNAL CONTROLS ARE CALLING FOR HEAT

Next: !p83, !f82

INSPECTION CONDENSATE

Next: p100, !f101